• Skip to primary navigation
  • Skip to main content
Motor and Generator Institute

Motor and Generator Institute

Emergency and Standby Power Education

  • My Training
  • Support
  • Main Site

CHEPP Certification Exam

We are experiencing issues with the exam at this time. Please check back later. If you try to take the exam at this time you will receive 130 questions. We are working on the issue.

Student’s have two (2) hours (120 minutes) to complete the 100-question exam. Once the exam is started you may not pause and return later. The exam MUST be finished once you click the “Start Quiz” button below.

If a question appears to have an incorrect answer, or you disagree with the wording, please write down the question during the exam. Upon completing the certification, you can submit a ticket for our instructor to review and respond.

Time limit: 0

Quiz Summary

0 of 130 Questions completed

Questions:

Information

You have already completed the quiz before. Hence you can not start it again.

Quiz is loading…

You must sign in or sign up to start the quiz.

You must first complete the following:

Results

Quiz complete. Results are being recorded.

Results

0 of 130 Questions answered correctly

Your time:

Time has elapsed

You have reached 0 of 0 point(s), (0)

Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)

Categories

  1. Evaluation 0%
  2. General 0%
  3. Healthcare 0%
  4. Maintenance 0%
  5. Operation 0%
  6. Personnel 0%
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13
  14. 14
  15. 15
  16. 16
  17. 17
  18. 18
  19. 19
  20. 20
  21. 21
  22. 22
  23. 23
  24. 24
  25. 25
  26. 26
  27. 27
  28. 28
  29. 29
  30. 30
  31. 31
  32. 32
  33. 33
  34. 34
  35. 35
  36. 36
  37. 37
  38. 38
  39. 39
  40. 40
  41. 41
  42. 42
  43. 43
  44. 44
  45. 45
  46. 46
  47. 47
  48. 48
  49. 49
  50. 50
  51. 51
  52. 52
  53. 53
  54. 54
  55. 55
  56. 56
  57. 57
  58. 58
  59. 59
  60. 60
  61. 61
  62. 62
  63. 63
  64. 64
  65. 65
  66. 66
  67. 67
  68. 68
  69. 69
  70. 70
  71. 71
  72. 72
  73. 73
  74. 74
  75. 75
  76. 76
  77. 77
  78. 78
  79. 79
  80. 80
  81. 81
  82. 82
  83. 83
  84. 84
  85. 85
  86. 86
  87. 87
  88. 88
  89. 89
  90. 90
  91. 91
  92. 92
  93. 93
  94. 94
  95. 95
  96. 96
  97. 97
  98. 98
  99. 99
  100. 100
  101. 101
  102. 102
  103. 103
  104. 104
  105. 105
  106. 106
  107. 107
  108. 108
  109. 109
  110. 110
  111. 111
  112. 112
  113. 113
  114. 114
  115. 115
  116. 116
  117. 117
  118. 118
  119. 119
  120. 120
  121. 121
  122. 122
  123. 123
  124. 124
  125. 125
  126. 126
  127. 127
  128. 128
  129. 129
  130. 130
  1. Current
  2. Review
  3. Answered
  4. Correct
  5. Incorrect
  1. Question 1 of 130
    1. Question

    An organization, office, or individual responsible for enforcing the requirements of a code or standard.

  2. Question 2 of 130
    2. Question

    The EPSS should function according to which of the following standards?

  3. Question 3 of 130
    3. Question

    Indicates a recommendation, or that which is advised but not required, in NFPA 110.

  4. Question 4 of 130
    4. Question

    Indicates a mandatory requirement NFPA 110.

  5. Question 5 of 130
    5. Question

    The purpose of NFPA 110, 8.4.2.2 is to protect the EPS from _______ and to protect the building’s essential loads.

  6. Question 6 of 130
    6. Question

    While normal power is available, the only subsystems in the EPSS that are working include the battery charger and block heater.

  7. Question 7 of 130
    7. Question

    Which branch supplier power to nurse call systems?

  8. Question 8 of 130
    8. Question

    Which circuits on the Essential Electrical Distribution System (EEDS) are NOT required to receive emergency power within 10 seconds.

  9. Question 9 of 130
    9. Question

    Circuits on the essential electrical distribution system are grouped into

  10. Question 10 of 130
    10. Question

    The role of the EPSS is to supply electrical power to ______ electric loads in the event of failure of the normal utility feeds.

  11. Question 11 of 130
    11. Question

    The critical branch may be split into two additional branches.

  12. Question 12 of 130
    12. Question

    Diesel powered generator sets used for emergency power in an acute care facility are designated as Type ___, Class ___, Level ___ generator sets, per NFPA 110.

  13. Question 13 of 130
    13. Question

    Healthcare facilities shall test their generator sets __ times a year, with testing intervals not less then __ days or exceeding __ days.

  14. Question 14 of 130
    14. Question

    NFPA 99, states that your Emergency System (Life Safety and Critical branches) will be online within 10 seconds.

  15. Question 15 of 130
    15. Question

    It is recommended the battery charger’s ammeterย be checked ________.ย 

  16. Question 16 of 130
    16. Question

    Before checking the electrolyte levels and the specific gravity of the electrolyte in a starting battery, the battery charger must be turned off and locked out at least __ minutes.ย 

  17. Question 17 of 130
    17. Question

    Battery charger output wiring shall be _________ connected to the primary side of the starter solenoid (positive) and the EPS frame (negative), or other grounding location.

  18. Question 18 of 130
    18. Question

    Battery charger output wiring shall be permanently connected to the primary side of the starter solenoid (positive) and the EPS frame (negative), or other grounding location.

  19. Question 19 of 130
    19. Question

    Battery charger output may be temporarily connected to the primary side of the starter solenoid (positive) and the EPS frame (negative), or other grounding location.

  20. Question 20 of 130
    20. Question

    It is recommended lead acid starting batteries be replaced every _____ months.

  21. Question 21 of 130
    21. Question

    Use the Lockout/Tagout procedures found in OSHA ______ to remove the generator from automatic operation at the control panel of the EPS.

  22. Question 22 of 130
    22. Question

    The EPS shall be heated as necessary to maintain the water jacket and battery temperature determined by the EPS manufacturer for cold start and load acceptance for the type of EPSS

  23. Question 23 of 130
    23. Question

    The EPS shall be cooled as necessary to maintain the water jacket and battery temperature determined by the EPS manufacturer for cold start and load acceptance for the type of EPSS

  24. Question 24 of 130
    24. Question

    Circuit breakers rated in excess of 600 volts for Level 1 system usage shall be exercised every ___ months

  25. Question 25 of 130
    25. Question

    Circuit breakers in excess of 600 volts shall be tested under simulated overload conditions every _____.

  26. Question 26 of 130
    26. Question

    The purpose of the _____ is to provide automatic disconnection of the generator from all circuits down-line from the generator in the event that power from the generator exceeds a specified value.

  27. Question 27 of 130
    27. Question

    NFPA 110 requires the main line circuit breaker to be exercised ____.

  28. Question 28 of 130
    28. Question

    NFPA 110 requires feeder breakers to be exercised _____.

  29. Question 29 of 130
    29. Question

    EPSS circuit breakers for Level 1 system usage, including main and feed breakers between the EPS and the transfer switch load terminals, shall be exercised _____ with the EPS in the off position.

  30. Question 30 of 130
    30. Question

    When checking the coolant system always wait ___ after the engine shuts down before removing the radiator cap.

  31. Question 31 of 130
    31. Question

    Which of the following PPE is recommended at a minimum for checking coolant level.

  32. Question 32 of 130
    32. Question

    The purpose of _____ is to alert personnel to EPSS abnormalities that would prevent the EPSS from operating as designed, and to indicate when normal and alternate (emergency) power is available.

  33. Question 33 of 130
    33. Question

    Battery blanket heaters and water/oil heaters should _____ operating after the prime mover starts.

  34. Question 34 of 130
    34. Question

    Testing all indicator lamps with the Press to Testย button on the control panel and on the remote annunciator panel are required only on a monthly basis.

  35. Question 35 of 130
    35. Question

    Automatic Transfer Switches sense the loss of electrical power and start the prime mover generally within __ to __ seconds.

  36. Question 36 of 130
    36. Question

    The purpose of the _____ is to convert the mechanical energy produced by the prime mover to electrical energy.

  37. Question 37 of 130
    37. Question

    The ______ drives the alternator, transforming mechanical energy into electricity.

  38. Question 38 of 130
    38. Question

    The term “Wet Stacking” indicates the presence of unburned _____ and/or _____ in the exhaust system.

  39. Question 39 of 130
    39. Question

    NFPA 110 requires exhaust temperatures be checked against manufacturer’s minimums if the generator is run or tested below __% of its nameplate rating

  40. Question 40 of 130
    40. Question

    If the engine does show evidence of wet stacking, an engine load runย test is mandatory for _ hours

  41. Question 41 of 130
    41. Question

    To check the exhaust system during weekly inspections, the engine must be _____.

  42. Question 42 of 130
    42. Question

    A condensate trap and drain valve shall be provided at the low points of exhaust piping, unless the piping is self-draining.

  43. Question 43 of 130
    43. Question

    Checking the fuel system during weekly inspections includes everything except which of the following.

  44. Question 44 of 130
    44. Question

    Fuel solenoid valves shall have a __________ operation, or a _____ bypass valve.

  45. Question 45 of 130
    45. Question

    A fuel bypass valve may be used to shut the EPS down in case of failure or emergency.

  46. Question 46 of 130
    46. Question

    The fuel manual bypass valve shall be visible and accessible and it’s purpose identified.

  47. Question 47 of 130
    47. Question

    Spark-ignited generator sets shall be exercised at least _____ with the available EPSS load for __ minutes or until the water temperature and the oil pressure have stabilized.

  48. Question 48 of 130
    48. Question

    A _____ ย is the source of electric power for the required capacity and quality for an emergency power supply system (EPSS).

  49. Question 49 of 130
    49. Question

    The purpose of the _____ is to regulate the output voltage of the alternator to a specified value.

  50. Question 50 of 130
    50. Question

    The room in which the EPS equipment is located shall not be used for other purposes that are not directly related to the EPS.

  51. Question 51 of 130
    51. Question

    Parts, tools, and manuals for routine maintenance and repair shall not be permitted to be stored in the EPS room.

  52. Question 52 of 130
    52. Question

    In a lead-acid battery, the specific gravity of the electrolyte in each cell is to be checked _____ adding any distilled water to raise the level of electrolyte.ย 

  53. Question 53 of 130
    53. Question

    Battery charger leads are ______ be connected directly to the positive and negative battery posts.ย 

  54. Question 54 of 130
    54. Question

    In diesel engines, mixing oil viscosity is acceptable due to the durability of the engine.

  55. Question 55 of 130
    55. Question

    NFPA 110 states storage batteries, including electrolyte levels or battery voltage, used in connection with systems shall be inspected _____.

  56. Question 56 of 130
    56. Question

    NFPA 110 recommends a battery load test should be performed _____.

  57. Question 57 of 130
    57. Question

    A lead-acid battery consisting of sealed cells furnished with a valve that opens to vent the battery whenever the internal pressure of the battery exceeds the ambient pressure by a set amount.

  58. Question 58 of 130
    58. Question

    A lead-acid battery consisting of cells that have electrodes immersed in liquid electrolyte.

  59. Question 59 of 130
    59. Question

    Battery conductance testing shall be permitted in lieu of the testing of specific gravity.

  60. Question 60 of 130
    60. Question

    Each prime mover shall be provided with storage battery units and a storage rack for each battery or battery unit.

  61. Question 61 of 130
    61. Question

    Each prime mover shall be provided with either storage battery units or storage rack for each battery or battery unit.

  62. Question 62 of 130
    62. Question

    Battery conductance testing shall not be permitted in lieu of the testing of specific gravity.

  63. Question 63 of 130
    63. Question

    Transfer switches of the _____ branch are set to operate either automatically (but delayed) or automatically.

  64. Question 64 of 130
    64. Question

    Self-acting equipment for transferring the connected load from one power source to another power source.

  65. Question 65 of 130
    65. Question

    A manually operated device used in conjunction with an automatic transfer switch to provide a means of directly connecting load conductors to a power source and disconnecting the automatic transfer switch.

  66. Question 66 of 130
    66. Question

    The purpose of _____ is to tie two or more EPSs together electrically for the purpose of producing additional current for circuits.

  67. Question 67 of 130
    67. Question

    The _____ is self-acting equipment for transferring the connected load from one power source to another power source.

  68. Question 68 of 130
    68. Question

    The purpose of _____ is to provide automatic disconnection of each transfer switch in the event of excessive current drain by the load downstream from the transfer switch.

  69. Question 69 of 130
    69. Question

    When performing weekly inspections, ensure all transfer switches are locked and that the lights showing _____ power is available are illuminated.ย 

  70. Question 70 of 130
    70. Question

    NFPA 110 states a ___________ source of power whenever the emergency generator is out of service.

    Hint
  71. Question 71 of 130
    71. Question

    NFPA 110 requires a portable or alternate source of power whenever the emergency generator is out of service.

    Hint
  72. Question 72 of 130
    72. Question

    NFPA 110 recommends a portable or alternate source of power whenever the emergency generator is out of service.

    Hint
  73. Question 73 of 130
    73. Question

    Records shall be created and maintained for all EPSS inspections, operational tests, exercising, repairs, and modifications.

  74. Question 74 of 130
    74. Question

    EPSS records should include date of the maintenance report, service personnel, and any unsatisfactory conditions including parts replaced.

  75. Question 75 of 130
    75. Question

    A written record of inspection, performance, exercising period, and repairs shall be regularly maintained and available for inspection by the authority having jurisdiction.

  76. Question 76 of 130
    76. Question

    Diesel-powered EPS’s that do not meet the requirements of NFPA 110, 8.4.2 shall be exercised _____ with the available EPSS load and shall be exercised _____ with supplemental loads at not less than __ percent of the EPS nameplate kW rating for __ continuous minutes.

  77. Question 77 of 130
    77. Question

    Suggested maintenance procedures and frequency should follow those recommended by the ________.

  78. Question 78 of 130
    78. Question

    NFPA 110, states that your Emergency System (Life Safety and Critical branches) will be on line within 10 seconds.

  79. Question 79 of 130
    79. Question

    The prime mover should be allowed to cool down for a minimum period of __ minutes before shut down.

  80. Question 80 of 130
    80. Question

    Running ______ generators as part of this weekly inspection can result in problems such as wet stacking.

  81. Question 81 of 130
    81. Question

    NFPA 110 states you shall have at least __ sets of instruction manuals for all major components of the EPSS.

  82. Question 82 of 130
    82. Question

    NFPA 110 states “Level 1” system instruction manuals shall be kept in a secure, convenient location, one set __________, and the other set in a separate location.

  83. Question 83 of 130
    83. Question

    NFPA 110 does not require special tools and testing devices necessary for routine maintenance be available.

  84. Question 84 of 130
    84. Question

    According to NFPA 110 the instruction manuals from the manufacturer shall include a detailed explanation of the operation of the system.

  85. Question 85 of 130
    85. Question

    According to NFPA 110 the instruction manuals from the manufacturer shall include instructions for routine maintenance.

  86. Question 86 of 130
    86. Question

    According to NFPA 110 the instruction manuals from the manufacturer shall include a parts list and part numbers.

  87. Question 87 of 130
    87. Question

    Operational tests after repair should last for a minimum of __ minutes.

  88. Question 88 of 130
    88. Question

    NFPA 110 states a routine maintenance and operational testing program shall be initiated immediately ____ the EPSS has passed acceptance tests.

  89. Question 89 of 130
    89. Question

    Operational tests after repair shall be initiated at the EPS (generator).

  90. Question 90 of 130
    90. Question

    NFPA 110 states a routine maintenance and operational testing program shall be initiated after completion of repairs that impact the operational reliability of the system.

  91. Question 91 of 130
    91. Question

    Operational tests after repair shall be initiated at an automatic transfer switch.

  92. Question 92 of 130
    92. Question

    Operational tests after repair should include the ย transfer of each automatic and manual transfer switch.

  93. Question 93 of 130
    93. Question

    The routine maintenance and operational testing program shall be based on all of the following except ______.

  94. Question 94 of 130
    94. Question

    Which OSHA code of federal regulation pertains to The Control of Hazardous Energy (Lockout/Tagout)?

  95. Question 95 of 130
    95. Question

    NFPA 110 requires a “Qualified Person” perform operation, maintenance, repair, and testing of an EPSS.

  96. Question 96 of 130
    96. Question

    The EPSS shall be maintained to ensure to a reasonable degree that the system is capable of supplying service within the time specified for the type and for the time duration specified for the class.

  97. Question 97 of 130
    97. Question

    NFPA 110, ____ EPSSs, including all appurtenant components, shall be inspected weekly and exercised under load at least monthly.

  98. Question 98 of 130
    98. Question

    The purpose of monthly testing is to _________________________.

  99. Question 99 of 130
    99. Question

    EPSSs, including all appurtenant components, shall be inspected _____ and exercised under load at least _____.

  100. Question 100 of 130
    100. Question

    NFPA 110, 8.4.1 pertains to activities which involve all EPSS components, with the generator, or EPS, representing but one.

  101. Question 101 of 130
    101. Question

    NFPA 110, 8.4.1 pertains to the generator (or EPS) only.

  102. Question 102 of 130
    102. Question

    NFPA, 8.4.1 states that an exercise shall be made on a weekly basis.

  103. Question 103 of 130
    103. Question

    NFPA, 8.4.1 states that an inspection only, not an exercise, shall be made on a weekly basis.

  104. Question 104 of 130
    104. Question

    EPSSs, including all appurtenant components, shall be inspected monthly and exercised under load at least semi-annually.

  105. Question 105 of 130
    105. Question

    EPSSs, including all appurtenant components, shall be inspected weekly and exercised under load at least quarterly.

  106. Question 106 of 130
    106. Question

    Most facilities perform the weekly inspection after the monthly load test.

  107. Question 107 of 130
    107. Question

    Most facilities perform the weekly inspections before the monthly load test.

  108. Question 108 of 130
    108. Question

    Which OSHA code of federal regulation pertains to Personal Protective Equipment?

  109. Question 109 of 130
    109. Question

    A _____ is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if ignored.

  110. Question 110 of 130
    110. Question

    A _____ sign or decal is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if ignored.

  111. Question 111 of 130
    111. Question

    _____ is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if ignored.

  112. Question 112 of 130
    112. Question

    _____ is used to notify people of installation, operation, or maintenance information which is important, but not hazard-related.

  113. Question 113 of 130
    113. Question

    Testing the EPS can be initiated by simulating a power outage using the test switch(es) on the ATSs or by opening a normal breaker.

  114. Question 114 of 130
    114. Question

    Load tests of generator sets [EPS’s] shall include complete cold starts.

  115. Question 115 of 130
    115. Question

    You are not allowed to start the EPS from the control panel of the EPS, let the EPS warm up,ย and then transfer the loads.

  116. Question 116 of 130
    116. Question

    According to NFPA 110, the date and time of day for required testing shall be decided by the ______.

  117. Question 117 of 130
    117. Question

    The date and time of day for required testing shall be decided by the owner.

  118. Question 118 of 130
    118. Question

    The date and time of required testing shall be determined by the service technician.

  119. Question 119 of 130
    119. Question

    Exercising the EPS for __ minutes at operating temperature or minimum exhaust temperature necessitates, under most circumstances, running the machine for ______ minutes including warm up and cool down.

  120. Question 120 of 130
    120. Question

    Diesel generator sets in service shall be exercised at least once monthly, for a minimum of __ minutes, under operating temperature conditions and at not less than __ percent of the EPS standby nameplate kW rating.

  121. Question 121 of 130
    121. Question

    Main and feeder circuit breakers shall be inspected _____ and a program for periodically exercising the components shall be established according to manufacturer’s recommendation.

  122. Question 122 of 130
    122. Question

    When testing Main and feeder circuit breakers you should not simulate overload trip conditions due to possibly damaging the breaker.

  123. Question 123 of 130
    123. Question

    The generator needs to run, with or without load, to be inspected.

  124. Question 124 of 130
    124. Question

    NFPA 110, _____ If the generator set is used for standby power or for peak load shaving, such use shall be recorded and shall be permitted to be substituted for scheduled operations and testing of the generator set, providing the same record as required by 8.3.4.

  125. Question 125 of 130
    125. Question

    According to NFPA 110, If the generator set is used for standby power or for peak load shaving, such use shall be recorded _____ be permitted to be substituted for scheduled operations and testing of the generator set.

  126. Question 126 of 130
    126. Question

    If the generator is used for standby power or for peak load shaving, such use shall be recorded and shall be permitted in lieu of scheduled operations and testing of the generator set.

  127. Question 127 of 130
    127. Question

    NFPA 110 states, starting time delays shall be set for a __ second minimum for diesel powered units and ___ second minimum for gas turbine units.

  128. Question 128 of 130
    128. Question

    Time delays for transfer to emergency power, after losing utility, should be set for 1-second.

  129. Question 129 of 130
    129. Question

    Time delays for restoration to normal power from emergency should be set for 1-minute.

  130. Question 130 of 130
    130. Question

    Time delays for restoration to normal power should be set for 5 minutes minimum.

Copyright © 2025 ยท Motor and Generator Institute

Login
Accessing this course requires a login. Please enter your credentials below!

Lost Your Password?
Register
Don't have an account? Register one!
Register an Account

Registration confirmation will be emailed to you.